  1. #Lon Integration Guide How To Program And
  2. #Lon Integration Guide Trial LONWORKS Networks
  3. #Lon Integration Guide Install And Service

Lon Integration Guide Install And Service

The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training.2 Internal Control Point Actions Hide/Show Control Points Linking, Building, and Trimming LONWORKS Component Objects in the FX Supervisor Linking the LONWORKS Component Objects Trimming LONWORKS Component Objects in the FX Supervisor Building LONWORKS Component Objects in the FX SupervisorEchelon, LON, Neuron, LonWorks, LonTalk, LonBuilder, NodeBuildeer, LonManager, LonUsers. Only qualified personnel should install and service the equipment. LIT Issued NovemDocument Introduction Related Documentation System Requirements Detailed Procedures Setting up a Station Installing the LX Support Pack Connecting to the Platform Installing the Distribution Files Installing the Wizard Service Resetting the Wizard Service Installing and Using LX Wizards Installing an LX Wizard Adding and Configuring a LONWORKS Network Commissioning the Device Device Upload Device Download Launching and Using an LX Wizard Launching an LX Wizard Launching the GPI Wizard Discovering an Existing Network Matching Devices Managing LONWORKS Programmable Controller Internal Points in the FX Supervisor Automatic Generation of Control Points Automatically Creating FX Supervisor Control Points Manually Creating Internal Control PointsLonTalk Integration to IntelliPak Rooftop Units (RTU) SSAAFFEETTYY WWAARRNNIINNGG. To the existing LON bus Stand-alone operation at the field control bus level for maximum performance and reliability Free topology transceiver technology simplifies wiring, uses standard network tools True integration with fire, security and digital video systems creates application opportunities never before availableThe LonWorks Option card utilizes Echelons latest ShortStack Micro Server platform to allow for consistent and seamless integration into LonWorks networks.1 LX Wizard and LON Integration Technical Bulletin Code No.

Lon Integration Guide How To Program And

This document does not include information on how to program and configure specific LX controllers. The wizards group device configuration properties in an intuitive programming interface. The wizards are the Facility Explorer versions of LNS plug-ins found with an LNS based network management tool. Data Sharing The Daikin PT-Link II LON-3 Technical Guide provides the follow-ing data sharing capabilities: Provides values from points on the DDC Controller side of the gateway to LON devices as if the values were originating from LON objects.3 LX Wizard and LON Integration Technical Bulletin Document Introduction LX Wizards offer a user-friendly interface to program and configure the LX controllers.

Lon Integration Guide Trial LONWORKS Networks

Installing the LX Support Pack The LX support pack contains software to install and configure the LX controllers. Wiring Guidelines for Twisted Pair LONWORKS Networks engineering bulletin.4 Detailed Procedures Setting up a Station This section details how to properly configure a Facility Explorer Supervisory station to support LX controllers on a LONWORKS network. 3network integration tool for open commercial and industrial LONWORKS networks. Service Internet access is required for LX Smart Installer application download. Table 2: LX Wizards System Requirements Operating System Minimum: Windows XP or later Recommended: Windows 7 Processor Minimum: Intel Pentium 4 or higher (or AMD equivalent) Recommended: Intel Core 2 Duo or higher (or AMD equivalent) Memory Minimum: 1 GB or as required by your chosen operating system Recommended: 2 GB or as required by your chosen operating system Hard Disk 500 MB free disk space Display Minimum: 800 x 600 Recommended: 1024 x 768 Network Interface An IP (Ethernet) network interface is required. You must install Facility Explorer software version 4.1 or later.

Run the support pack executable file (.exe). You must be logged in with Administrator rights. Close all running programs on your computer.

Figure 1: Starting the LX Controllers Support Pack Installation Note: To install the preloaded applications, install and run the JCI-ABCS Smart Installer Client software. The Choose Destination Location window appears. For Windows XP, run the support pack installation executable file. For Windows 7, right-click the support pack installation executable file and select Run As Administrator.

Figure 17: Adding the WizardService to Services Tree Upgrading an Existing Station for the Wizard Service To upgrade the Bcp Server Service to the Wizard Service, use this installation method. The Wizard Service is now added to the Services folder of the tree of the station. 413 Note: Locate the Services tree within the Config tree of the station.

To access the Software Manager, expand the Platform tree of the FX Supervisor. Run the Software Manager to verify that the JCI LX Support Pack is installed. Connect to the Platform of the FX20/60/70 you intend to upgrade. Before upgrading your station, verify you have the JCI LX Support Pack installed on your FX Workbench. Upgrade the Bcp Server Service to the Wizard Service to use the upgraded Wizards and new LX controllers.

In the Nav side bar, access the Wizard Service property sheet. To configure the Wizard Service: 1. 1316 Configuring the Wizard Service When configuring the Wizard Service, you can define properties such as the communication port and the maximum number of simultaneous connections. If you installed the JCI LX Support Pack on your Workbench version, a.dist file is available. Expand the Platform view and double-click the Distribution File Installer. Figure 18: Upgrade Results 3.

When the service is not enabled, a disabled status appears. When the service is enabled, an OK status appears. Table 3: Wizard Service Property Sheet Parameters (Part 1 of 2) Field Description Status (Read-Only) Fault Cause (Read-Only) Enabled Port Max Connections Version (Read-Only) Min Version (Read-Only) Number Connections (Read-Only) BACnet Settings LONWORKS Settings TagUpdateLatency Figure 23: Wizard Service Property Sheet Displays the status of the Wizard Service. Table 3 defines the Wizard Service property sheet.

lon integration guide

Transmit Timer set to Milli Sec512. 1617 Table 3: Wizard Service Property Sheet Parameters (Part 2 of 2) Field Description Comm Config Comm Config/Auto Update Wizard Settings Create Proxy Point Description Default Numeric Point Precision Tunneling Settings WizardService_LonLegacy Client Path Server Connections Si Save Data Supported Field Bus Wire Sheet Layout Settings For our controllers, we strongly recommend using the following settings: Repeat Timer set to Milli Sec96. The default settings is 500 milliseconds. Not applicable Displays time during which the device message tags are buffered before the messages are sent to the GPI. Displays the number of clients (wizards) currently running and using the Wizard Service.

lon integration guide

Wizard service extension to manage the application-specific and line-by-line programmable controllers. When connected to an FX Supervisor whose IP address is not directly accessible from your computer, tunneling may be used as a connection method, when properly configured. Numeric precision for floating point numbers displayed by proxy points created with the Create Points device action. This description can be used to provide information on a Px Page. Allows the GPI block property Description to be created as a description property under proxy points with the Create Points device action.

If true, maintains compatibility for controllers operating with LNS versions less than or equal to 3.0. The number of supported connection is set in Max Connections. Sets the server connection parameters. We strongly recommend you do not change this field.

Table 4 lists the settings of the parameter. Figure 24 displays the WizardService_LonLegacy parameter and associated settings in FX Workbench. 1718 The WizardService_LonLegacy parameter of the property sheets supports the use of the LX Configuration Wizards. Controls LONMARK object layout on the property sheet for specific GPI device types. Lists the network types supported by the Wizard Service.

Displays the ports that the station is using to communicate with the legacy wizards. Disable the server by setting this field to False. Enable the server by setting this field to True. Enables or Disables the WizardService_LonLegacy parameter. If there is a problem with the WizardService, this field lists the possible cause of the problem. If the server is enabled (Enabled field set to True), an status is displayed.